TWCSv3使用说明
WINGFIELDSCALE
WEIGHMODE COUNTMODE COMMON BUTTONSONEVERYSCREEN: -WINGFIELDSCALELOGO–whichwill actas ashort cutkeyto asettings“favoritemenu”or “QuickMenu”administrator can selectwhatitems to putinthis“Short Cut”keyundersettingsinQuickMenu. Wingfield ScaleLogowill be located intopleft ofeveryscreen. Itis passwordprotected. Whenpressed itwillneedto activatedafull keypad.If user accidently pressesthiskeyhe canpressanywhereoutside the keypadand itwillclosethe keypadand resume normalfunction. ThePasswordis 1937. -BACK BUTTON–Takesuser back to the previousscreen Located inthelowerrightcornerofeveryscreen -HOME BUTTON–Takesuserto Firstscreen, initialscreen. Actsasareset button.Clearing weights, zeroing scales,sample, counts, etc. Startoverbutton When UCountModeis on,HomeButtonwill resetthescaleand returnyouto Initial2button“WEIGHMODE”“COUNT MODE”screen (Slide1)Thatcan change. When UCountModeis Off,HomeButtonwillresetthe scale.Screenwill appearthesame.GrossWeightwillbe in Large Screen(screen 1)Netwill be in Smallleft screen (screen 2)andTareWeightwill bein small rightscreen (Screen 3). All zeroedafterHomebuttonis pressed. HOMEBUTTONis located inthelowerbottomcenterofeveryscreen. Setting -SETTINGSBUTTON– Settingbuttonis located in toprightofeveryscreen. Itispassword protected. Whenpressed itwillneedto activatedafull keypad.If user accidentlypresses thiskey he can press anywhereoutside thekeypadand itwillclosethekeypadand resume normalfunction.Passwordis 23640. -CalculatorButton–Availableoneveryscreen. Expandsto fullfunctionCalculator.Buttoncan be enabledand disabledin SETTINGS, -Wifi Connectivity/SignalStrength -BluetoothConnectivity/SignalStrength -BatteryIndicator–Showsstrength,and if itis charging UCountMode:ON FirstScreen: 2 Buttons“WEIGHMODE”and“COUNTMODE” WEIGHMODE WeighMode-Takesyoutoaweighmodewiththreescreensonelargemainscreen#1,2smaller,#2onlowerleftand#3onlowerright.Gross,Net,Tare. Therewillbe5Buttonsontheright(andanoptionalPrintbutton) -TARE–Whichwilldropdowntoanumerickeypadtoenterinthe tare weight.OnceTareweightisenteredtheNetweightmustbereplacedastheweightin the#1 “large”or “Main”screen. -MODE–PressingitwillreplaceGrossweightWithNetweightin#1screenandGROSSWEIGHTWILL3screens.Gross,Net,Tare(andAverage,PieceWeight,whenincountmode). -UNITS–Pressingunitswillflowthemthroughtheavailableunits(kg,lb,oz,troyoz,gr).Theseunitscanbeturnsonandoffin thesettingsmenu. -ZERO–Typicalzerofunction -PRINT–TherewillbeanoptionalprintbuttonBelowUnitsthatcanbeturnonorOffbasedonneedinsettings.Thiswillprinttoprinterviaoutputandprotocolthat hasbeen setupinSettingsmenu -SAMPLE–GreenButtonwillallowusertocount.SimilarprotocoltoWCS PressingSamplewillzeroouttopscaleanddisplayonthe#1MainScreen“Add10andpressSAMPLEORaddadifferentquantityandkeyinthatnewquantityandpress SAMPLE”.Thedefault“10”canbechangedinSETTINGS,COUNTING,DEFUALTSAMPLESIZE. Ifsampleistoolight/small“ERROR”willbedisplayedandthewords“SAMPLEQUANTITYTOOSMALL.REMOVEPARTSFROMSCALE.PRESSSAMPLETOBEGINAGAIN ANDINCREASEYOURSAMPLESIZE/QUANTITY. IfSamplesizeisgood ScalewillSwitchtoScale2anddisplaycountsonthatareonscale2 -Ifscale2isDisabledinSETTINGS,SCALESETUP,SCALE2ENABLE/DISABLE.AfterpressingSAMPLEthesecondtimethescalewillnotswitchtoscale2. -IfAutobaseSwitchingisturnoffinSETTINGS,COUNTING,AUTOBASESWITCHING.UserwillhavetomanuallyselectScale2.AfterpressingSampleforthe secondtimethequantitythatisdisplayed(withAutobaseSwitchingOff)countofscale1willbedisplayanduserwillhavetomanuallyselectScale2toget #1 mainscreentodisplayscale#2dataquantity. -Administratorcansetthescaleupto taketheinitialSAMPLEonscale2andcountonscale2.ThisisaccomplishedinSETTINGS,COUNTING,SAMPLESCALEASSIGN, PRE-SAMPLESCALE1or2,AFTERSAMPLESCALE1or2. -Administratorhastheoptionof enablingAutoZeroScale2inSETTINGS,COUNTING,AUTO-ZEROSCALE2ON/OFF.Whenthisisenabled,(andAutobaseSwitchingis Enabled)Scale2willbezeroedwhenuserpressesSAMPLEforthesecondtimeandscaleswitchestoScale2todisplaycountsandweightandinstructionsfornext step. Userisinstructedto“PlaceContainerofpartsonLargeScale.Entertare weightthenpressTARE”. -Usercanchangetheirtareweightby enteringanothertareweightanditwillNOTaccumulatebut ratheroverwritetheprevioustareweight.Tareweightisclearly visibleintheTareWeightscreen(#3LowerRightScreen).NetWeightWillbeinthe#2Screen(lowerLeft).PressingModeherewilltoggletheuserthroughdisplayingGross,Net, Tare,andAPWinthosescreens. Mode1–Screen1:Quantity,Screen2:NetWeight,Screen3:TareWeight Mode2–Screen1:Quantity,Screen2:TareWeight,Screen3:AveragePieceWeight(availableineveryunit) Mode3–Screen1:Gross Weight,Screen2:NetWeight,Screen3:TareWeight Mode4–Screen1:NetWeight,Screen2:GrossWeight,Screen3:TareWeight ScaleSelect: Scale1andScale2buttonswillchangewhichscaleisdisplayedinthe#1 “main”“large”screen.IfthereisNoscaleconnectedtoscale2 comportorifthereisa connectionerror(example:cordhasbeencutordamaged)scalewillread“NoConnection”totherightoftheScale2 button. Totherightofscale1andscale2arelistofpossibleerrorsscale1 orscale2 couldhave ConnectionError(Shownforeitherscale1 orscale2) Underload Overload–anerrorindicationtoomuchweighthasbeenappliedtoloadcellanditisbad (Weneedalistoferrorsandtheyneedtobeeasilyundersood.)
SINGLESCALE MODE DUALSCALE MODE COUNTMODE: UsercanselectSINGLESCALEMODEorDUALSCALEMODE - thisscreencanbeonlybe bypassedbyadministratorinsetupbygoingintoSETTINGS,SCALE SETUP,SCALE 2 DISABLE.Thenscalewouldoperateasabenchscale only.OnlythenwouldtheSINGLESCALEMODE/DUALSCALEMODEbebypassed.Ifuserisoperatingthescale inDUALSCALEMODEuserwillalwayshavetheoptiontouse SINGLESCALEMODE.Usercanlocktheiranswerandnothavetoanswerthisquestioneverytime.PressingHomebuttonwouldresetlocksandsendbackto1stslide/screen. SINGLESCALEMODE: Userwillbeasked“Doyouknowthe tare weightofyourcontainer?”“YES”or“NO”(Slide7) - Usercanlockthisscreenassumingsotheywillnothavetoanswerthisquestionagainandagain.Thescalewillthenafterfinishingcountingskipthisquestionand proceedtothenext.Hittingthehomebuttonwillresetthe“lock”andhavetheuserbacktothebeginning.Usercanalsousethebackbuttontonavigatetothisscreenandunlock thisif theyneededto. “DoyouknowtheTAREweightofyourcontainer?”YES - WhenuserselectsYESthenscalewillthenpromptuserto“ADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”thenpress“COUNT”(Slide8) The10defaultsamplesizecanbesetinSETTINGS,COUNTING, DEFAULTSAMPLESIZE usercanadd10uniformpartsandif theyarelargeenoughusercanpress“COUNT”buttonandproceedtonextscreen - Ifpartsaresmallanduserneedtochangesamplesizetheycanpress“CHANGESAMPLE”whichwillopenakeypadtoentertheirnewsamplesize.They canenteranysamplesizetheywant.Thenumbertheyenterwillbethenumberthatcomesupthenexttimetheuserperformsacount(Example:Default samplesizeis10.Userchangesit to3.thenextcountitwillread3).IftheuserpressesHomeButtonitwillsoftresetthescalebacktothedefaultsample sizeof10. - Ifusersamplespartsthatare tooLightweightanerrorscreenwillappearstating“ERRORSAMPLESIZE TOOSMALLREMOVEPARTSFROMSCALETHENPRESS “RESET” TOBEGINAGAINANDINCREASEYOURSAMPLEQUANTITY(Slide9) whenuserpresses“RESET”buttonthescalewillresetand re-zeroand returntoscreen“ADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”THEN PRESS “COUNT”
APW–AveragePieceWeight–buttoncanbepressedatthisscreenallowingtheusertobypassthesamplingprocessandenterindirectlytheAPWofthe particularitem.(Slide18).UserneedtohavetheabilitytochangetounitofmeasurefortheAPWtheyareentering.ItmightbeinLB,KG,OZ,GRAMS,etc. Needtohavetheallavailable. Pressing“NEXT”willproceedtothefollowingscreen(slide11) - Userwillbepromptedto“PLACECONTAINEROFPARTSONSMALLSCALEENTERTAREWEIGHTTHENPRESSTARE” Userwillseethecount“PCS”increase(anddecrease)intheavailablescreenasweightinapplied(andtakenoff)tothescale. UsercankeyintheirTAREweightwithavailablekeypadandseethenumbersastheykeythemin,theycandeleteanumberiftheyenteredoninwrongandrekeyit. -Pressingthe“TARE”buttonproceedyoutotheFinalScreen FinalScreen(screen12) Userwillhaveafinalreadingofthecountin#1screen,NetweightinScreen#2,andTareweightinScreen#3. Userwillbeprompted“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” UsercanenternewTAREweightandtheTAREweightwillnotadd/sumtothepreviousTAREweight.ITwilloverwrite/replacethepreviousTAREweight. FullfunctionofTARE,MODE,UNITS,PRINT,ZERO,etc.UsercanselectScale2anduseascale2,applypartsandseeacountthere,immediatelyTARE,etc. Pressing“NEXTCOUNT”buttonresetscountandproceedsusertothenextcountbyreturningtheusertoSINGLESCALEDUALSCALEscreenoriftheyareusingitas abench(scale1only)itwouldreturntheuserto“DOYOUKNOWTHETAREWEIGHTOFYOPURCONTAINER”YESorNO.Iftheuserhaslockedouttheanswertothat questionandisusingonlyasscale1 thenit wouldthenproceedhimtothe“ADD10PARTSTOSMALLSCALEORCHANGESAMPLE”
DO YOUKNOWTHETAREWEIGHTOF YOURCONTAINER?
YES NO
ADD 10PARTSTO SMALLSCALE OR
THENPRESS CHANGESAMPLE
COUNT
APW
ERROR
SAMPLESIZETOOSMALL
REMOVEPARTSFROMSCALE
THENPRESS RESET TO BEGINAGAIN
ANDINCREASEYOUR SAMPLEQUANTITY
PLACECONTAINEROFPARTSONLARGESCALE ENTERTAREWEIGHTTHENPRESSTARE
0PCS ENTERTAREWEIGHT
0.0
PLACECONTAINEROFPARTSONSMALLSCALE ENTERTAREWEIGHTTHENPRESSTARE
0PCS ENTERTAREWEIGHT
0.0
Quantity
RETURNSAMPLETO LARGESCALE ANDRECORDFINALCOUNT. TO PROCEED,PRESSNEXT COUNT.
TARE 0000PCS NEXT COUNT
NET
0.000LBS
SCALE 1
TARE
0.000LBS MODE
ZERO
Quantity
RECORDFINALCOUNT. TO PROCEED,PRESSNEXT COUNT.
TARE 0000PCS NEXT COUNT
NET
0.000LBS
SCALE 1
TARE
0.000LBS MODE
ZERO
SAMPLE
WEIGHT GROSS
NET
0.000LBS TARE TARE
UNITS
SCALE 1 0.000LBS
APW PRINT*
ZERO
Add 10 & PressSAMPLE Oradda differentquantity& keyinanewquantitythenpressSAMPLE SAMPLE
QUANTITY
NET 0.000LBS
TARE
0PIECES
0.000LBS TARE
ZERO SCALE 1 APW
ERRORsampleqtytoosmall,removesamplefromscale. PressSAMPLEto beginagain&increasesampleqty. SAMPLE
QUANTITY
NET 0.000LBS
TARE
0PIECES
0.000LBS TARE
ZERO SCALE 1 APW
QUANTITY Placecontainerof parts on large scale Enter tare weightthenpressTARE
TARE
UNITS SAMPLE NET
0.000LBS TARE
0.000LBS
ZERO SCALE 1 APW
0.00
UNIT APW
PRESS NEXT WHENFINISHED
ADDPARTSTO CONTAINER
0PIECES
THENPRESS
NEXT “DoyouknowtheTAREweightofyourcontainer?”NO -IfuseranswersNOtoContainerTAREweightquestionthenextscreenwillread“PLACEEMPTYCONTAINERONSCALETHENPRESSSAMPLEPRESSTOSTART”(Slide 22).WhenuserpressesSAMPLEbuttonthescalewilltareoffwhateverisonthescale(theemptycontainer),liketheWCS/WCS2.Thescalethenproceedstothenextscreen havingtaredoffthecontainer. -Thenextscreen(slide8).Functionhasbeendescribedbefore.Useraddssampleandpressescountorchangestheirsample.(APW,Error,DefaultSampleSize). -Thenextscreen(slide19).Useraddspartsto container.Screenonthescreenshowsthatthecountincreasingasuserplacesweightinthecontainer/on thescale.UserpressesNEXTtoproceedtothefinalscreen(slide12). -FinalScreenwillbefullfunctionasdescribedearlier.Willstate“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” -Countisdisplayedin#1Screen.NETweightisScreen#2,andTareweightinScreen#3.Tareweightwillbecalculatedfromwhatwas taredduringthe earlierstep ofplacingtheemptycontaineronthescaleandpressingSAMPLE. -UponpressingNEXTCOUNT,userwillbereturnedto3possiblescreens,asdescribedearlierin“DoyouknowtheTAREweightof yourcontainer?”YES -UseralsohastheoptionofpressingHOMEbuttonwhichwouldsoftresettheuserbacktoWEIGHMODECOUNTMODE.
SINGLESCALE/DUALSCALE - DUALSCALE -UserselectsDUALSCALE - Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7) - Userselects“YES” -Userproceedstonextscreen“ADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8) -Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button. - Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize). -Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale2before switchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE2ON/OFF. - ScalehasnowswitchedtoScale2andthedisplayonthescreenisregisteringScale2. -Userproceedstothenextscreen(Slide10)andisinstructedto“PLACECONTAINEROFPARTSONLARGESCALE.ENTERTAREWEIGHTTHENPRESSTARE” -Userseesvalue/countincreaseordecreaseinthemainscreenasthecontainerisplacedonScale2(LargeScale). -Userusesthekeypadonscreentoenterthetare weight.UsercanseethevaluetheyareenteringinthescreenabovekeypadandPressesTAREtoenterthat weight/valueandproceedtonextscreen. -NextscreenisthefinalScreen(slide12except“scale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen#2,TareScreen#3. -Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” - Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2. -FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4possiblescreens: - SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen - DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen. - ADD10PARTSTOSMALLSCALEORCHANGESAMPLE - IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st ScreenWEIGHMODE/COUNTMODE(slide1) SINGLESCALE/DUALSCALE - DUALSCALE - UserselectsDUALSCALE -Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7) - Userselects“NO” -Userproceedstonextscreen“ADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8) -Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button. - Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize). -Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale 2beforeswitchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE 2 ON/OFF. -ScalehasnowswitchedtoScale2 -ScreenPromptsusertoPLACEEMPTYCONTAINERONSCALETHENPRESSTARE(slide23). -UserplacestheiremptycontaineronthescaleandpressesZERO.ThiswilltarethecontaineroffScale2andproceedtonextscreen. -Whateverweight(container)theuserplacesonthescaleandthentaresoffbypressingtheZERObuttonwillbedisplayedinthefinalscreen,screen#3 astheTareweight. -NextScreen(slide19)promptstheuserto“ADDPARTSTOCONTAINERTHENPRESSNEXT” - Thisscreenhasascreenthatshowsuseranactivecount(PCS) forwhatisbeingaddedtothescale(orremoved). -UserpressesNEXTandproceedstothenextscreenwhichisthefinalscreen -ThefinalScreen(slide12except“scale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen #2,TareScreen#3.Tareweightwould becalculatedfromtheprocessofTaring/zeroingtheemptycontainerperformedinslide23. -Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” -Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2. - FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4 possiblescreens: - SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen - DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen. - ADD10PARTSTOSMALLSCALEORCHANGESAMPLE - IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st ScreenWEIGHMODE/COUNTMODE(slide1)
PLACE EMPTY CONTAINER ON SCALE
THENPRESS
SAMPLE PRESS TOSTART
PLACEEMPTYCONTAINERONSCALE
THENPRESS
TARE
SCALE SETUP CALIBRATION COUNTING
CONNECTIVITY UNITS DISPLAY
TROUBLESHOOTING QUICKMENU CHECKWEIGHER
PRINTER PresstheSETTINGSGearbuttontoaccesstheSetting/backend/setupmenu: - Administratorwillbepromptedtoenterinapassword(23640)whichisnotvisibletothepersonenteringitonakeypadthatappearswithanenterbutton. - UponenteringthepasswordcorrectlytheopeningSETTINGSpage(slide24)willdisplayallbasicoptionsforAdministratortomakeadjustmentsofsetupscale. - InsideSETTINGS,CALIBRATIONis theonlyheadingthatisPasswordProtected(passwordis54321) SCALESETUP - SCALE1 orSCALE2
- SCALE1- –ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale1ordisableit.Scale1wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaWeighonlyDisplay/Indicator.Thisis rarebutdoeshappen.DefaultwillbeENABLED.Thestatusofthescalewill bevisible -CAPACITYSCALE1-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defaultvalueis Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide25) -RESOLUTIONSCALE1–thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe RESOLUTIONbox -FILTERINGSCALE1–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3 -ZEROTRACKINGSCALE1–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions DEFAULTsettingis0 whichisOFFordisabled. -MOTIONDELAYSCALE1–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1 second. -MOTIONDIVISIONSSCALE1– DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0 divisions.DEFAULTis3divisions -PUSHBUTTONZEROSETTINGSSCALE1–keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity. SCALE2-
–ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale2ordisableit.Scale2wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaSINGLESCALEMODEorbenchscaleonly.DoingthiswouldeliminatetheSINGLESCALEDUALSCALEquestioninthe countingprocessasit wouldbeinSINGLESCALEMODEonly.DEFAULTWILLBEENABLED -CAPACITYSCALE2-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defasultvalueis Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide31) -RESOLUTIONSCALE2–thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe RESOLUTIONbox -FILTERINGSCALE2–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3.Settingisvisible. -ZEROTRACKINGSCALE2–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions DEFAULTsettingis0whichisOFFordisabled.Settingisvisible -MOTIONDELAYSCALE2–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1 second.Settingisvisible - MOTIONDIVISIONSSCALE 2–DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0 divisions.DEFAULTis1divisions.Settingisvisible -PUSHBUTTONZEROSETTINGSSCALE2–keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity.Settingisvisible
UNITS(Slide35) - DEFAULTCALIBRATIONUNIT - Administratorisabletoselectdefaultunitsforcalibration.UnitsavailableareLB,KG.Theunitisvisible. - AVAILABLEUNITS - Administratorcanselectwhatunitsare availabletotheenduserwhentheenduserpressestheUNITbutton.Availableunitsare:LB,KG,Grams,OZ, TroyOZ.InonlyLBandKGisselectedthentheuserwillonlybeabletoselectunitsof LBandKG.orifLBistheonlyunitselectedhereLB willbethe onlyunitthatwillbeselectablebytheUNITbutton.Allunitswillbevisibleandselectable. CALIBRATION(Slide31) - SCALE1orSCALE2–Calibrationmenuwillholdthevaluesfromtheprevioustimethescalewascalibrated - Scalewillalsohavetheabilitytoholdcalibrations“counts”orinordertocalibratewithoutweights. - Scale2calibrationwillpromptadminforthebasetheyarecalibratingtowithfullalphanumerickeypad.Scalewillbeabletosaveupto10scalesinhistory.Whencalibratingeach timeitwilldefaulttothepreviousbaseentered(EXAMPLEBC-126).Whenthescaleisturnedonthescalewillprompttheuserwithafullscreenprompt“AREYOUCONNECTEDTO BASEBC-126orthebasetheAdministratorhadenteredinduringcalibration.This featurecanbedisabledinSETTINGS,COUNTING,BASEPROMPTINGON/OFF.WitheachBase enteredinthescalewillholdinmemorythecountsassociatedwithZEROandtheCALIBRATIONWEIGHT.EachcalibrationafterthefirsttheAdminwillhavetheoptionofselecting COUNTSCALIBRATIONandperformacalibrationwithoutphysicalweights
SCALE 1 CALBRATIONTYPE - COUNTSorSPAN -SPANCALIBRATIONSCALE1 –ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe3typesofZERO: - NEWZERO–Scaletakesanew zero,withnothingonthescale. - LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour calibrationweightandcalibratethescale. - ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket) whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan. -CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback upandrunningsometimes. -Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened. - AdministratorthenpressesCALIBRATIONbutton. -aDisplayshowingweightwillappear.AndtheCalibrationwillbegin. -IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptof“Add CalibrationWeight” -IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdminto“AddCalibrationWeight”.Useraddscal weightandpresses ENTER. -ThescalewillthendisplayCALIBRATIONCOMPLETE IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.
COUNTSCALIBRATIONSCALE1 AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues. SCALE2 CALBRATIONTYPE - COUNTSorSPAN -SPANCALIBRATIONSCALE2 FirstscreenthatcomesupwillprompttheAdminforthebasethatheiscalibratingto“ISBC-126THEBASEYOUARECALIBRATINGTO?YES/NO -IfYESthenproceedtoCalibrationpage.IfNOthenAdmincanenterinanewbasewithafullalphanumerickeypad.Total30charactermax –ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe4typesofZERO: - NEWZERO–Scaletakesanew zero,withnothingonthescale. - LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour calibrationweightandcalibratethescale. - ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket) whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan. - ZEROCOUNTS–Establishingzerobasedoncountsvalue -CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback upandrunningsometimes. -Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened. -AdministratorthenpressesCALIBRATIONbutton. -aDisplayshowingweightwillappear.AndtheCalibrationwillbegin. -IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptof“Add CalibrationWeight” -IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdminto“AddCalibrationWeight”.Adminaddscalweight,Admincan seethe1,000LBonthedisplayandpressesENTER.Thescalemaygo to1003LBthenpressEnterscalewilladjustto1000beforestatingCALIBRATIONCOMPLETE -ThescalewillthendisplayCALIBRATIONCOMPLETE IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.
COUNTSCALIBRATIONSCALE1 AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues. COUNTING
DEFAULTSAMPLESIZE–Admincansetthedefaultsamplesizefrom1to500.Thisiswhatwillshowinslides8&14.Thiswillbechangedbyadropdown menuwithenteratthebottom,Defaultis10 AUTOBASESWITCHING–AdmincanturnautobaseswitchingON/OFF.ThisisappliedtoCountingwhenin“WEIGHMODE”.IfOFF,aftertheinitialsample istakencountremainsonscaleone,usermustmanuallyselect“SCALE2”toswitchtoSCALE2.IfON,aftertheinitialsampleistakenthecount/weighwill beswitchtoSCALE2automatically.DEFAULTisON SAMPLESCALE1/2–Admincansetwhichscaletheywanttoactassamplescale.95%of thetimeuserwouldSAMPLEonscale1,howeverthereare timesthat requireustosampleonSCALE2becausetheweightofthepartistooheavy.Inthatsituationuserwouldsampleonscale2andcountonscale2.DefaultisON UCOUNTMODEON/OFF–AdmincanturnUCountModeonandoff.WhenONuserwillflowthroughthescreensof COUNTMODE,SINGLESCALE/DUALSCALE,“DO YOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”….. IfOFF,thenuserwillonlybeabletoweighandcountin“WEIGHMODE”. AUTOZEROSCALE2ON/OFF–IfsettoON,Scale2willbeautomaticallyzeroedwhenscaleswitchestoscale2. IfOFF,scalewillneedtobemanually Zeroedortared BASEPROMPTINGON/OFF–IfsettoON,whenscaleisturnonitwillpromptuser“ISSCALECONNECTEDTOSCALE ?”. IfOFF,itwillnot prompt.
DISPLAY SLEEPTIMER–AdmincanturnSLEEPTIMERON/OFF. - ON- settimedurationforscreento“sleep”.Admincanselectpresettimes.30sec,1,2,3,4,5,10,15,20,25,30,35,40,45,50,55,60minutes - OFF–Screenwillstayon - DEFAULTisONandsetto10 minutes BRIGHTNESS–Admincansetthebrightnessofthescreen,10-100%by10(10,20,30,etc).DEFAULTis80 CALCULATOR–ON/OFF- Admincanselectwhethertheywantthecalculatoroptionandicontoappear APW–ON/OFF–AdmincanturnonandofftheAPWbutton.IfOFF,thebuttonwillnotbevisible.IFON,thebuttonwillbevisibleandactive. PRINT–ON/OFF–AdmincanselecttoturnonoroffthePRINTbutton. MODE–ON/OFF–AdmincanselecttoturnonorofftheMODEbutton COLORTHEME–Colorofbackgroundandbuttonscanbesethere.Have5differentpredeterminedsettings LANGUAGE–BeabletoselectLanguagefortheentirescale.EnglishandSpanisharemostimportant TROUBLESHOOTING mV/VOutput–Admincanseerealtimethemillivoltpervoltoutputoftheloadcell.Scale1 andScale2 EXCITATIONVOLTAGE–AdmincanseerealtimeVoltagereadingoffthemainboard.Scale1andScale2. CURRENTBATTERYCONDITION–Cycles,amps,capacity,chargetimeremaining,voltage,etc HARDRESET–PasswordProtected(1937)Askareyousure?YES/NO.Thisresetsthescaleto factorydefaultsettings. QUICKMENU Admincanselectfromallthemenuwhatitemsfromthemenuhewantsinhereforquickaccess
CONNECTIVITY WIFI–AdmincanselectWifinetwork,enterpasswords,full rangeofnecessaryrequirements.NeedtoshowNetworkStrengthonmainscreen Wifisettings.Selectnetwork,forgetnetwork,ShowWifisignalstrength.ScalecanbeaWIFIsource?Willscalehaveitsownwebserver BLUETOOTH–AdmincanperformsettingsforBluetooth,connecttoprinters,finddevices,sync,etc.Needtoshowbluetoothconnectivityonmainscreen COMMPORTS- Adminsetsettingsfor: USBPorts–SettingsforUSBPorts,selectingwhatisinsertedintotheUSBPort.IfitisaJumpDriveScaleshould…….USBportneedstobea dataUSB port.Minimumof2USBports.Need4. SERIALPORTS–AdmincanselectSerialPorts.Outputwouldbeaprinter,inputwouldbeascanner ETHERNETPORTS–Admincansetsettingsfor: - TCP/IP1 - TCP/IP2 - FTP MISCROSDPORT–LiketohaveavailableMicroSDport
PRINTER
MODEL/DRIVER–Admincanselectdriverforprintermodeltoprintto.DriversDownloadedintoscalefromfactoryshouldbe Zebra,HP,Starandgeneric(Ticket/Strip printer),.Candownloaddrivervia,Wireless,USB,Ethernet,ifdriverisnotavailable TICKETEDITOR–AdmincaneditanddesigntickettobeprintedfromPRINTonthe“WEIGHMODE”ScreenorFinalCountScreen.TicketEditorwillprintSelectionof MODEscreensandtimedatestamp.Barcodes,2Dcodes,WYSIWYG(WhatYouSeeIsWhatYouGet) Editor CHECKWEIGHER TARGET–AdmincansetTARGETWeight.Scalewillhowclosetheyare tothe targetwithintherange RANGE–AdmincansetUNDER(lower)andOVER(upper)weightlimitforcheckweigher.Ifwithintheweightrangeallisnormal.IfweightinlowerthantheUNDER limitthenentirescreenbackgroundwillturnred.IfOVER,thenentirebackgroundwillturnred. DIGITALINPUT/OUTPUT–Admincandeterminewhattheywanttoenabletothescaletodowiththatinformation.EXAMPLE:IfOVER,thescalecansendaDIGITAL OUTPUTsignaltoanactuatorvalvethatwillstopanassemblylinebecausethepartbeingmanufactureredisnotdeterminedweight. EXAMPLE:TARGETis17Lbs Under15isredscreenanderror.Signalsentout.Over20 error.IdealTargetis17andeachweighmentwillbetrackedtoseehowclose Underis15Lbs theyare to17 Overis20Lbs
ENABLE DISABLE
ENABLE
COUNTS CALIBRATION SPANCALIBRATION
SCALE1 SCALE2
COUNTS 0.000LBS
CALIBRATE CALIBRATE SPANCALIBRATION
SCALE1 SCALE2
CALIBRATE CALIBRATE UNITS
DEFAULT CALIBRATIONUNITS SELECTUNITS
oLB oKG oLB oKG oOZ oTOZ oG COUNTING
DEFAULTSAMPLE SIZE
10PCS AUTOBASESWITCH ON OFF SAMPLESCALE 1 2
U COUNT ON OFF AUTOZEROSCALE2 ON OFF BASE PROMPT ON OFF
CONNECTIVITY
WIFI COMM PORTS -USB -SERIAL ETHERNETPORTS -TCIP -FTP
BLUETOOTH MICROSD PORTS
WINGFDSCALE I-ÞV
QUICKMENU
SLEEPTIMER
10min CALCULATOR ON OFF
APWBUTTON ON OFF PRINTBUTTON ON OFF MODEBUTTON ON OFF
ON OFF CHECKWEIGHER
PRINTER
MODEL/DRIVER TICKETEDITOR
EXIT
SAVECHANGES?