TWCSv3使用说明
-WINGFIELDSCALELOGO–whichwill actas ashort cutkeyto asettings“favoritemenu”or “QuickMenu”administrator can selectwhatitems to putinthis“Short Cut”keyundersettingsinQuickMenu. Wingfield ScaleLogowill be located intopleft ofeveryscreen. Itis passwordprotected. Whenpressed itwillneedto activatedafull keypad.If user accidently pressesthiskeyhe canpressanywhereoutside the keypadand itwillclosethe keypadand resume normalfunction. ThePasswordis 1937. -BACK BUTTON–Takesuser back to the previousscreen Located inthelowerrightcornerofeveryscreen -HOME BUTTON–Takesuserto Firstscreen, initialscreen. Actsasareset button.Clearing weights, zeroing scales,sample, counts, etc. Startoverbutton When UCountModeis on,HomeButtonwill resetthescaleand returnyouto Initial2button“WEIGHMODE”“COUNT MODE”screen (Slide1)Thatcan change. When UCountModeis Off,HomeButtonwillresetthe scale.Screenwill appearthesame.GrossWeightwillbe in Large Screen(screen 1)Netwill be in Smallleft screen (screen 2)andTareWeightwill bein small rightscreen (Screen 3). All zeroedafterHomebuttonis pressed. HOMEBUTTONis located inthelowerbottomcenterofeveryscreen. Setting -SETTINGSBUTTON– Settingbuttonis located in toprightofeveryscreen. Itispassword protected. Whenpressed itwillneedto activatedafull keypad.If user accidentlypresses thiskey he can press anywhereoutside thekeypadand itwillclosethekeypadand resume normalfunction.Passwordis 23640. -CalculatorButton–Availableoneveryscreen. Expandsto fullfunctionCalculator.Buttoncan be enabledand disabledin SETTINGS, -Wifi Connectivity/SignalStrength -BluetoothConnectivity/SignalStrength -BatteryIndicator–Showsstrength,and if itis charging
2 Buttons“WEIGHMODE”and“COUNTMODE” WEIGHMODE WeighMode-Takesyoutoaweighmodewiththreescreensonelargemainscreen#1,2smaller,#2onlowerleftand#3onlowerright.Gross,Net,Tare. Therewillbe5Buttonsontheright(andanoptionalPrintbutton) -TARE–Whichwilldropdowntoanumerickeypadtoenterinthe tare weight.OnceTareweightisenteredtheNetweightmustbereplacedastheweightin the#1 “large”or “Main”screen. -MODE–PressingitwillreplaceGrossweightWithNetweightin#1screenandGROSSWEIGHTWILL3screens.Gross,Net,Tare(andAverage,PieceWeight,whenincountmode). -UNITS–Pressingunitswillflowthemthroughtheavailableunits(kg,lb,oz,troyoz,gr).Theseunitscanbeturnsonandoffin thesettingsmenu. -ZERO–Typicalzerofunction -PRINT–TherewillbeanoptionalprintbuttonBelowUnitsthatcanbeturnonorOffbasedonneedinsettings.Thiswillprinttoprinterviaoutputandprotocolthat hasbeen setupinSettingsmenu -SAMPLE–GreenButtonwillallowusertocount.SimilarprotocoltoWCS PressingSamplewillzeroouttopscaleanddisplayonthe#1MainScreen“Add10andpressSAMPLEORaddadifferentquantityandkeyinthatnewquantityandpress SAMPLE”.Thedefault“10”canbechangedinSETTINGS,COUNTING,DEFUALTSAMPLESIZE. Ifsampleistoolight/small“ERROR”willbedisplayedandthewords“SAMPLEQUANTITYTOOSMALL.REMOVEPARTSFROMSCALE.PRESSSAMPLETOBEGINAGAIN ANDINCREASEYOURSAMPLESIZE/QUANTITY. IfSamplesizeisgood ScalewillSwitchtoScale2anddisplaycountsonthatareonscale2 -Ifscale2isDisabledinSETTINGS,SCALESETUP,SCALE2ENABLE/DISABLE.AfterpressingSAMPLEthesecondtimethescalewillnotswitchtoscale2. -IfAutobaseSwitchingisturnoffinSETTINGS,COUNTING,AUTOBASESWITCHING.UserwillhavetomanuallyselectScale2.AfterpressingSampleforthe secondtimethequantitythatisdisplayed(withAutobaseSwitchingOff)countofscale1willbedisplayanduserwillhavetomanuallyselectScale2toget #1 mainscreentodisplayscale#2dataquantity. -Administratorcansetthescaleupto taketheinitialSAMPLEonscale2andcountonscale2.ThisisaccomplishedinSETTINGS,COUNTING,SAMPLESCALEASSIGN, PRE-SAMPLESCALE1or2,AFTERSAMPLESCALE1or2. -Administratorhastheoptionof enablingAutoZeroScale2inSETTINGS,COUNTING,AUTO-ZEROSCALE2ON/OFF.Whenthisisenabled,(andAutobaseSwitchingis Enabled)Scale2willbezeroedwhenuserpressesSAMPLEforthesecondtimeandscaleswitchestoScale2todisplaycountsandweightandinstructionsfornext step. Userisinstructedto“PlaceContainerofpartsonLargeScale.Entertare weightthenpressTARE”. -Usercanchangetheirtareweightby enteringanothertareweightanditwillNOTaccumulatebut ratheroverwritetheprevioustareweight.Tareweightisclearly visibleintheTareWeightscreen(#3LowerRightScreen).NetWeightWillbeinthe#2Screen(lowerLeft).PressingModeherewilltoggletheuserthroughdisplayingGross,Net, Tare,andAPWinthosescreens. Mode1–Screen1:Quantity,Screen2:NetWeight,Screen3:TareWeight Mode2–Screen1:Quantity,Screen2:TareWeight,Screen3:AveragePieceWeight(availableineveryunit) Mode3–Screen1:Gross Weight,Screen2:NetWeight,Screen3:TareWeight Mode4–Screen1:NetWeight,Screen2:GrossWeight,Screen3:TareWeight
Scale1andScale2buttonswillchangewhichscaleisdisplayedinthe#1 “main”“large”screen.IfthereisNoscaleconnectedtoscale2 comportorifthereisa connectionerror(example:cordhasbeencutordamaged)scalewillread“NoConnection”totherightoftheScale2 button. Totherightofscale1andscale2arelistofpossibleerrorsscale1 orscale2 couldhave ConnectionError(Shownforeitherscale1 orscale2) Underload Overload–anerrorindicationtoomuchweighthasbeenappliedtoloadcellanditisbad (Weneedalistoferrorsandtheyneedtobeeasilyundersood.)
MODE DUALSCALE MODE COUNTMODE: UsercanselectSINGLESCALEMODEorDUALSCALEMODE - thisscreencanbeonlybe bypassedbyadministratorinsetupbygoingintoSETTINGS,SCALE SETUP,SCALE 2 DISABLE.Thenscalewouldoperateasabenchscale only.OnlythenwouldtheSINGLESCALEMODE/DUALSCALEMODEbebypassed.Ifuserisoperatingthescale inDUALSCALEMODEuserwillalwayshavetheoptiontouse SINGLESCALEMODE.Usercanlocktheiranswerandnothavetoanswerthisquestioneverytime.PressingHomebuttonwouldresetlocksandsendbackto1stslide/screen. SINGLESCALEMODE: Userwillbeasked“Doyouknowthe tare weightofyourcontainer?”“YES”or“NO”(Slide7) - Usercanlockthisscreenassumingsotheywillnothavetoanswerthisquestionagainandagain.Thescalewillthenafterfinishingcountingskipthisquestionand proceedtothenext.Hittingthehomebuttonwillresetthe“lock”andhavetheuserbacktothebeginning.Usercanalsousethebackbuttontonavigatetothisscreenandunlock thisif theyneededto. “DoyouknowtheTAREweightofyourcontainer?”YES - WhenuserselectsYESthenscalewillthenpromptuserto“ADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”thenpress“COUNT”(Slide8) The10defaultsamplesizecanbesetinSETTINGS,COUNTING, DEFAULTSAMPLESIZE usercanadd10uniformpartsandif theyarelargeenoughusercanpress“COUNT”buttonandproceedtonextscreen - Ifpartsaresmallanduserneedtochangesamplesizetheycanpress“CHANGESAMPLE”whichwillopenakeypadtoentertheirnewsamplesize.They canenteranysamplesizetheywant.Thenumbertheyenterwillbethenumberthatcomesupthenexttimetheuserperformsacount(Example:Default samplesizeis10.Userchangesit to3.thenextcountitwillread3).IftheuserpressesHomeButtonitwillsoftresetthescalebacktothedefaultsample sizeof10. - Ifusersamplespartsthatare tooLightweightanerrorscreenwillappearstating“ERRORSAMPLESIZE TOOSMALLREMOVEPARTSFROMSCALETHENPRESS “RESET” TOBEGINAGAINANDINCREASEYOURSAMPLEQUANTITY(Slide9) whenuserpresses“RESET”buttonthescalewillresetand re-zeroand returntoscreen“ADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”THEN PRESS “COUNT”
APW–AveragePieceWeight–buttoncanbepressedatthisscreenallowingtheusertobypassthesamplingprocessandenterindirectlytheAPWofthe particularitem.(Slide18).UserneedtohavetheabilitytochangetounitofmeasurefortheAPWtheyareentering.ItmightbeinLB,KG,OZ,GRAMS,etc. Needtohavetheallavailable. Pressing“NEXT”willproceedtothefollowingscreen(slide11) - Userwillbepromptedto“PLACECONTAINEROFPARTSONSMALLSCALEENTERTAREWEIGHTTHENPRESSTARE” Userwillseethecount“PCS”increase(anddecrease)intheavailablescreenasweightinapplied(andtakenoff)tothescale. UsercankeyintheirTAREweightwithavailablekeypadandseethenumbersastheykeythemin,theycandeleteanumberiftheyenteredoninwrongandrekeyit. -Pressingthe“TARE”buttonproceedyoutotheFinalScreen FinalScreen(screen12) Userwillhaveafinalreadingofthecountin#1screen,NetweightinScreen#2,andTareweightinScreen#3. Userwillbeprompted“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” UsercanenternewTAREweightandtheTAREweightwillnotadd/sumtothepreviousTAREweight.ITwilloverwrite/replacethepreviousTAREweight. FullfunctionofTARE,MODE,UNITS,PRINT,ZERO,etc.UsercanselectScale2anduseascale2,applypartsandseeacountthere,immediatelyTARE,etc. Pressing“NEXTCOUNT”buttonresetscountandproceedsusertothenextcountbyreturningtheusertoSINGLESCALEDUALSCALEscreenoriftheyareusingitas abench(scale1only)itwouldreturntheuserto“DOYOUKNOWTHETAREWEIGHTOFYOPURCONTAINER”YESorNO.Iftheuserhaslockedouttheanswertothat questionandisusingonlyasscale1 thenit wouldthenproceedhimtothe“ADD10PARTSTOSMALLSCALEORCHANGESAMPLE”
DO YOUKNOWTHETAREWEIGHTOF YOURCONTAINER?
CHANGESAMPLE
APW
ERROR
REMOVEPARTSFROMSCALE
THENPRESS RESET TO BEGINAGAIN
ENTERTAREWEIGHT
0.0
![]() ![]() ![]() ![]() ![]()
ENTERTAREWEIGHT
0.0
![]() ![]() ![]() ![]() ![]()
RETURNSAMPLETO LARGESCALE ANDRECORDFINALCOUNT.
NEXT COUNT
![]() ![]() ![]() ![]()
NET
0.000LBS
SCALE 1
TARE
MODE
ZERO
RECORDFINALCOUNT.
NEXT COUNT
![]() ![]() ![]() ![]()
NET
0.000LBS
SCALE 1
TARE
MODE
ZERO
TARE
![]() ![]() ![]() ![]() ![]()
0.000LBS
APW PRINT*
Add 10 & PressSAMPLE Oradda differentquantity& keyinanewquantitythenpressSAMPLE SAMPLE
0.000LBS
TARE
0PIECES
0.000LBS TARE
APW
ERRORsampleqtytoosmall,removesamplefromscale. PressSAMPLEto beginagain&increasesampleqty. SAMPLE
0.000LBS
TARE
0PIECES
0.000LBS TARE
APW
QUANTITY Placecontainerof parts on large scale
SAMPLE NET
0.000LBS TARE
0.000LBS
APW
0.00
UNIT APW
NEXT WHENFINISHED
0PIECES
“DoyouknowtheTAREweightofyourcontainer?”NO -IfuseranswersNOtoContainerTAREweightquestionthenextscreenwillread“PLACEEMPTYCONTAINERONSCALETHENPRESSSAMPLEPRESSTOSTART”(Slide 22).WhenuserpressesSAMPLEbuttonthescalewilltareoffwhateverisonthescale(theemptycontainer),liketheWCS/WCS2.Thescalethenproceedstothenextscreen havingtaredoffthecontainer. -Thenextscreen(slide8).Functionhasbeendescribedbefore.Useraddssampleandpressescountorchangestheirsample.(APW,Error,DefaultSampleSize). -Thenextscreen(slide19).Useraddspartsto container.Screenonthescreenshowsthatthecountincreasingasuserplacesweightinthecontainer/on thescale.UserpressesNEXTtoproceedtothefinalscreen(slide12). -FinalScreenwillbefullfunctionasdescribedearlier.Willstate“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” -Countisdisplayedin#1Screen.NETweightisScreen#2,andTareweightinScreen#3.Tareweightwillbecalculatedfromwhatwas taredduringthe earlierstep ofplacingtheemptycontaineronthescaleandpressingSAMPLE. -UponpressingNEXTCOUNT,userwillbereturnedto3possiblescreens,asdescribedearlierin“DoyouknowtheTAREweightof yourcontainer?”YES -UseralsohastheoptionofpressingHOMEbuttonwhichwouldsoftresettheuserbacktoWEIGHMODECOUNTMODE.
SINGLESCALE/DUALSCALE - DUALSCALE -UserselectsDUALSCALE - Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7) - Userselects“YES” -Userproceedstonextscreen“ADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8) -Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button. - Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize). -Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale2before switchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE2ON/OFF. - ScalehasnowswitchedtoScale2andthedisplayonthescreenisregisteringScale2. -Userproceedstothenextscreen(Slide10)andisinstructedto“PLACECONTAINEROFPARTSONLARGESCALE.ENTERTAREWEIGHTTHENPRESSTARE” -Userseesvalue/countincreaseordecreaseinthemainscreenasthecontainerisplacedonScale2(LargeScale). -Userusesthekeypadonscreentoenterthetare weight.UsercanseethevaluetheyareenteringinthescreenabovekeypadandPressesTAREtoenterthat weight/valueandproceedtonextscreen. -NextscreenisthefinalScreen(slide12except“scale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen#2,TareScreen#3. -Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” - Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2. -FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4possiblescreens: - SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen - DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen. - ADD10PARTSTOSMALLSCALEORCHANGESAMPLE - IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st ScreenWEIGHMODE/COUNTMODE(slide1) SINGLESCALE/DUALSCALE - DUALSCALE - UserselectsDUALSCALE -Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7) - Userselects“NO” -Userproceedstonextscreen“ADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8) -Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button. - Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize). -Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale 2beforeswitchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE 2 ON/OFF. -ScalehasnowswitchedtoScale2 -ScreenPromptsusertoPLACEEMPTYCONTAINERONSCALETHENPRESSTARE(slide23). -UserplacestheiremptycontaineronthescaleandpressesZERO.ThiswilltarethecontaineroffScale2andproceedtonextscreen. -Whateverweight(container)theuserplacesonthescaleandthentaresoffbypressingtheZERObuttonwillbedisplayedinthefinalscreen,screen#3 astheTareweight. -NextScreen(slide19)promptstheuserto“ADDPARTSTOCONTAINERTHENPRESSNEXT” - Thisscreenhasascreenthatshowsuseranactivecount(PCS) forwhatisbeingaddedtothescale(orremoved). -UserpressesNEXTandproceedstothenextscreenwhichisthefinalscreen -ThefinalScreen(slide12except“scale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen #2,TareScreen#3.Tareweightwould becalculatedfromtheprocessofTaring/zeroingtheemptycontainerperformedinslide23. -Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT” -Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2. - FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4 possiblescreens: - SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen - DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen. - ADD10PARTSTOSMALLSCALEORCHANGESAMPLE - IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st ScreenWEIGHMODE/COUNTMODE(slide1)
![]() ![]() ![]() ![]() ![]()
PLACE EMPTY CONTAINER ON SCALE
SAMPLE PRESS TOSTART
![]() ![]() ![]() ![]() ![]()
PLACEEMPTYCONTAINERONSCALE
TARE
CALIBRATION COUNTING
UNITS DISPLAY
TROUBLESHOOTING QUICKMENU CHECKWEIGHER
![]() ![]() ![]()
PresstheSETTINGSGearbuttontoaccesstheSetting/backend/setupmenu: - Administratorwillbepromptedtoenterinapassword(23640)whichisnotvisibletothepersonenteringitonakeypadthatappearswithanenterbutton. - UponenteringthepasswordcorrectlytheopeningSETTINGSpage(slide24)willdisplayallbasicoptionsforAdministratortomakeadjustmentsofsetupscale. - InsideSETTINGS,CALIBRATIONis theonlyheadingthatisPasswordProtected(passwordis54321) SCALESETUP - SCALE1 orSCALE2
- SCALE1- –ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale1ordisableit.Scale1wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaWeighonlyDisplay/Indicator.Thisis rarebutdoeshappen.DefaultwillbeENABLED.Thestatusofthescalewill bevisible -CAPACITYSCALE1-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defaultvalueis Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide25) -RESOLUTIONSCALE1–thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe RESOLUTIONbox -FILTERINGSCALE1–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3 -ZEROTRACKINGSCALE1–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions DEFAULTsettingis0 whichisOFFordisabled. -MOTIONDELAYSCALE1–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1 second. -MOTIONDIVISIONSSCALE1– DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0 divisions.DEFAULTis3divisions -PUSHBUTTONZEROSETTINGSSCALE1–keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity. SCALE2-
–ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale2ordisableit.Scale2wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaSINGLESCALEMODEorbenchscaleonly.DoingthiswouldeliminatetheSINGLESCALEDUALSCALEquestioninthe countingprocessasit wouldbeinSINGLESCALEMODEonly.DEFAULTWILLBEENABLED -CAPACITYSCALE2-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defasultvalueis Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide31) -RESOLUTIONSCALE2–thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe RESOLUTIONbox -FILTERINGSCALE2–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3.Settingisvisible. -ZEROTRACKINGSCALE2–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions DEFAULTsettingis0whichisOFFordisabled.Settingisvisible -MOTIONDELAYSCALE2–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1 second.Settingisvisible - MOTIONDIVISIONSSCALE 2–DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0 divisions.DEFAULTis1divisions.Settingisvisible -PUSHBUTTONZEROSETTINGSSCALE2–keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity.Settingisvisible
UNITS(Slide35) - DEFAULTCALIBRATIONUNIT - Administratorisabletoselectdefaultunitsforcalibration.UnitsavailableareLB,KG.Theunitisvisible. - AVAILABLEUNITS - Administratorcanselectwhatunitsare availabletotheenduserwhentheenduserpressestheUNITbutton.Availableunitsare:LB,KG,Grams,OZ, TroyOZ.InonlyLBandKGisselectedthentheuserwillonlybeabletoselectunitsof LBandKG.orifLBistheonlyunitselectedhereLB willbethe onlyunitthatwillbeselectablebytheUNITbutton.Allunitswillbevisibleandselectable. CALIBRATION(Slide31) - SCALE1orSCALE2–Calibrationmenuwillholdthevaluesfromtheprevioustimethescalewascalibrated - Scalewillalsohavetheabilitytoholdcalibrations“counts”orinordertocalibratewithoutweights. - Scale2calibrationwillpromptadminforthebasetheyarecalibratingtowithfullalphanumerickeypad.Scalewillbeabletosaveupto10scalesinhistory.Whencalibratingeach timeitwilldefaulttothepreviousbaseentered(EXAMPLEBC-126).Whenthescaleisturnedonthescalewillprompttheuserwithafullscreenprompt“AREYOUCONNECTEDTO BASEBC-126orthebasetheAdministratorhadenteredinduringcalibration.This featurecanbedisabledinSETTINGS,COUNTING,BASEPROMPTINGON/OFF.WitheachBase enteredinthescalewillholdinmemorythecountsassociatedwithZEROandtheCALIBRATIONWEIGHT.EachcalibrationafterthefirsttheAdminwillhavetheoptionofselecting COUNTSCALIBRATIONandperformacalibrationwithoutphysicalweights
SCALE 1 CALBRATIONTYPE - COUNTSorSPAN -SPANCALIBRATIONSCALE1 –ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe3typesofZERO: - NEWZERO–Scaletakesanew zero,withnothingonthescale. - LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour calibrationweightandcalibratethescale. - ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket) whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan. -CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback upandrunningsometimes. -Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened. - AdministratorthenpressesCALIBRATIONbutton. -aDisplayshowingweightwillappear.AndtheCalibrationwillbegin. -IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptof“Add CalibrationWeight” -IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdminto“AddCalibrationWeight”.Useraddscal weightandpresses ENTER. -ThescalewillthendisplayCALIBRATIONCOMPLETE IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.
COUNTSCALIBRATIONSCALE1 AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues. SCALE2 CALBRATIONTYPE - COUNTSorSPAN -SPANCALIBRATIONSCALE2 FirstscreenthatcomesupwillprompttheAdminforthebasethatheiscalibratingto“ISBC-126THEBASEYOUARECALIBRATINGTO?YES/NO -IfYESthenproceedtoCalibrationpage.IfNOthenAdmincanenterinanewbasewithafullalphanumerickeypad.Total30charactermax –ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe4typesofZERO: - NEWZERO–Scaletakesanew zero,withnothingonthescale. - LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour calibrationweightandcalibratethescale. - ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket) whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan. - ZEROCOUNTS–Establishingzerobasedoncountsvalue -CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback upandrunningsometimes. -Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened. -AdministratorthenpressesCALIBRATIONbutton. -aDisplayshowingweightwillappear.AndtheCalibrationwillbegin. -IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptof“Add CalibrationWeight” -IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdminto“AddCalibrationWeight”.Adminaddscalweight,Admincan seethe1,000LBonthedisplayandpressesENTER.Thescalemaygo to1003LBthenpressEnterscalewilladjustto1000beforestatingCALIBRATIONCOMPLETE -ThescalewillthendisplayCALIBRATIONCOMPLETE IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.
COUNTSCALIBRATIONSCALE1 AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues. COUNTING
DEFAULTSAMPLESIZE–Admincansetthedefaultsamplesizefrom1to500.Thisiswhatwillshowinslides8&14.Thiswillbechangedbyadropdown menuwithenteratthebottom,Defaultis10 AUTOBASESWITCHING–AdmincanturnautobaseswitchingON/OFF.ThisisappliedtoCountingwhenin“WEIGHMODE”.IfOFF,aftertheinitialsample istakencountremainsonscaleone,usermustmanuallyselect“SCALE2”toswitchtoSCALE2.IfON,aftertheinitialsampleistakenthecount/weighwill beswitchtoSCALE2automatically.DEFAULTisON SAMPLESCALE1/2–Admincansetwhichscaletheywanttoactassamplescale.95%of thetimeuserwouldSAMPLEonscale1,howeverthereare timesthat requireustosampleonSCALE2becausetheweightofthepartistooheavy.Inthatsituationuserwouldsampleonscale2andcountonscale2.DefaultisON UCOUNTMODEON/OFF–AdmincanturnUCountModeonandoff.WhenONuserwillflowthroughthescreensof COUNTMODE,SINGLESCALE/DUALSCALE,“DO YOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”….. IfOFF,thenuserwillonlybeabletoweighandcountin“WEIGHMODE”. AUTOZEROSCALE2ON/OFF–IfsettoON,Scale2willbeautomaticallyzeroedwhenscaleswitchestoscale2. IfOFF,scalewillneedtobemanually Zeroedortared BASEPROMPTINGON/OFF–IfsettoON,whenscaleisturnonitwillpromptuser“ISSCALECONNECTEDTOSCALE ?”. IfOFF,itwillnot prompt.
DISPLAY SLEEPTIMER–AdmincanturnSLEEPTIMERON/OFF. - ON- settimedurationforscreento“sleep”.Admincanselectpresettimes.30sec,1,2,3,4,5,10,15,20,25,30,35,40,45,50,55,60minutes - OFF–Screenwillstayon - DEFAULTisONandsetto10 minutes BRIGHTNESS–Admincansetthebrightnessofthescreen,10-100%by10(10,20,30,etc).DEFAULTis80 CALCULATOR–ON/OFF- Admincanselectwhethertheywantthecalculatoroptionandicontoappear APW–ON/OFF–AdmincanturnonandofftheAPWbutton.IfOFF,thebuttonwillnotbevisible.IFON,thebuttonwillbevisibleandactive. PRINT–ON/OFF–AdmincanselecttoturnonoroffthePRINTbutton. MODE–ON/OFF–AdmincanselecttoturnonorofftheMODEbutton COLORTHEME–Colorofbackgroundandbuttonscanbesethere.Have5differentpredeterminedsettings LANGUAGE–BeabletoselectLanguagefortheentirescale.EnglishandSpanisharemostimportant TROUBLESHOOTING mV/VOutput–Admincanseerealtimethemillivoltpervoltoutputoftheloadcell.Scale1 andScale2 EXCITATIONVOLTAGE–AdmincanseerealtimeVoltagereadingoffthemainboard.Scale1andScale2. CURRENTBATTERYCONDITION–Cycles,amps,capacity,chargetimeremaining,voltage,etc HARDRESET–PasswordProtected(1937)Askareyousure?YES/NO.Thisresetsthescaleto factorydefaultsettings. QUICKMENU Admincanselectfromallthemenuwhatitemsfromthemenuhewantsinhereforquickaccess
CONNECTIVITY WIFI–AdmincanselectWifinetwork,enterpasswords,full rangeofnecessaryrequirements.NeedtoshowNetworkStrengthonmainscreen Wifisettings.Selectnetwork,forgetnetwork,ShowWifisignalstrength.ScalecanbeaWIFIsource?Willscalehaveitsownwebserver BLUETOOTH–AdmincanperformsettingsforBluetooth,connecttoprinters,finddevices,sync,etc.Needtoshowbluetoothconnectivityonmainscreen COMMPORTS- Adminsetsettingsfor: USBPorts–SettingsforUSBPorts,selectingwhatisinsertedintotheUSBPort.IfitisaJumpDriveScaleshould…….USBportneedstobea dataUSB port.Minimumof2USBports.Need4. SERIALPORTS–AdmincanselectSerialPorts.Outputwouldbeaprinter,inputwouldbeascanner ETHERNETPORTS–Admincansetsettingsfor: - TCP/IP1 - TCP/IP2 - FTP MISCROSDPORT–LiketohaveavailableMicroSDport
PRINTER
MODEL/DRIVER–Admincanselectdriverforprintermodeltoprintto.DriversDownloadedintoscalefromfactoryshouldbe Zebra,HP,Starandgeneric(Ticket/Strip printer),.Candownloaddrivervia,Wireless,USB,Ethernet,ifdriverisnotavailable TICKETEDITOR–AdmincaneditanddesigntickettobeprintedfromPRINTonthe“WEIGHMODE”ScreenorFinalCountScreen.TicketEditorwillprintSelectionof MODEscreensandtimedatestamp.Barcodes,2Dcodes,WYSIWYG(WhatYouSeeIsWhatYouGet) Editor CHECKWEIGHER TARGET–AdmincansetTARGETWeight.Scalewillhowclosetheyare tothe targetwithintherange RANGE–AdmincansetUNDER(lower)andOVER(upper)weightlimitforcheckweigher.Ifwithintheweightrangeallisnormal.IfweightinlowerthantheUNDER limitthenentirescreenbackgroundwillturnred.IfOVER,thenentirebackgroundwillturnred. DIGITALINPUT/OUTPUT–Admincandeterminewhattheywanttoenabletothescaletodowiththatinformation.EXAMPLE:IfOVER,thescalecansendaDIGITAL OUTPUTsignaltoanactuatorvalvethatwillstopanassemblylinebecausethepartbeingmanufactureredisnotdeterminedweight. EXAMPLE:TARGETis17Lbs Under15isredscreenanderror.Signalsentout.Over20 error.IdealTargetis17andeachweighmentwillbetrackedtoseehowclose Underis15Lbs theyare to17 Overis20Lbs
CALIBRATION SPANCALIBRATION
COUNTS 0.000LBS
SPANCALIBRATION
UNITS
DEFAULT CALIBRATIONUNITS SELECTUNITS
oKG oLB oKG oOZ oTOZ oG COUNTING
DEFAULTSAMPLE SIZE
AUTOBASESWITCH ON OFF SAMPLESCALE 1 2
ON OFF AUTOZEROSCALE2 ON OFF BASE PROMPT ON OFF
WIFI COMM PORTS -USB -SERIAL ETHERNETPORTS -TCIP -FTP
![]() ![]()
SLEEPTIMER
10min CALCULATOR ON
APWBUTTON ON
PRINTBUTTON ON OFF MODEBUTTON ON OFF
OFF
PRINTER
EXIT
SAVECHANGES?
下一篇EW100 Series
|